The XR Series are low cost solutions for high
performance HV Capacitor Charging applications offering extremely low
pulse to pulse repeatability. The XR-DC allows continuous DC operation
with low ripple, and low stored energy. Employing Lambda Americas
patented phase shifting parallel resonant converter topology the XR
series supplies offers unrivalled pulse to pulse repeatability at
extreme repetition rates. Unlike other manufacturers who claim high
performance in data sheets, the XR series has demonstrated 0.1% pulse
to pulse repeatability at repetition rates to 2kHz, in real field
applications. The
XR802 shares many features with the standard 802, but in addition it
is equipped with a phase shifting resonant inverter configuration
which allows the charging current to be gradually reduced as the
load voltage approaches the programmed level. This feature allows
the XR802 supply to repetitively charge capacitive loads with pulse
to pulse repeatability of 0.1% or better at repetition rates of 1kHz
or more. This is a particular requirement of high performance
systems where charge voltage variability results in process or dose
variability and a reduction in process quality. Lambda Americas is the
only power supply manufacturer currently offering this advanced
performance in a compact 8kJ/sec air cooled package. |
AC Input
208 VAC or 400 VAC,
3 phase, 50/60Hz.
(Please specify at the time of order).
Average Charging Rate
6000 J/s at rated Output Voltage.
Peak Charging Rate
7000 J/s at rated Output Voltage.
Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6,
10, 15, 20, 30 kV.
All models continuously variable from 10 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.
Polarity
Available as fixed Positive or
Negative, Please Specify.
High
Voltage Assembly
Oil Insulated HV section with optional air
insulation at voltages below 6kV
Output
Connector/Cable
| Output
Voltage |
Connector |
Cable |
| 1-6kV |
Amphenol
HN |
RG-8/U |
| >6kV |
Proprietary |
DS 2214SSJ |
Input
Connector
VDE, UL, CSA, approved.
Power
Factor
Passive PFC 0.85 min
Efficiency
Better than 85%
Stored
Energy
Less than 0.3 Joules all models.
|
Stability
0.2% per hour after 1 hour
warm-up.
Pulse to
Pulse Repeatability
+/- 0.1% to 250Hz standard.
+/- 0.1% to 1kHz option.
Temperature
Coefficient
100 PPM per oC
Ambient
Temperature
Storage: -40 to +80 oC
Operating:0 to +45 oC
Humidity
10-90% Non-condensing
Protection
The power supply is protected against open
circuits, short circuits, overloads and arcs.
Agency
Approvals
Certification to EN60950 (pending)
Mechanical
19"(482mm) x 17"(432mm) x 8.75"(222mm)
Accessories
- Detachable 10 foot HV cable
- Operating manual
Remote Control
Via 25pin d-type connector on rear panel. Click
here for details
Options
| Suffix-RFI |
Optional external filter which reduces
conducted emissions. (400VAC only) |
| Suffix-5V |
0 to
+5 volt program (0 to full-scale output) |
| Suffix-LP |
Latching
overload protection |
| Suffix-RS |
Remote
sense |
| Suffix-CT |
Optional
internal contactor for OEM only (standard on L/S
models) |
|